The FX81-DL from Dakota NDT is the top-of-the-range ultrasonic flaw detector with an advanced thickness gauge: a large sunlight-readable color display, a high-performance receiver (0–110 dB) and a complete set of sizing toolkits.
- Top-of-the-range flaw detector : + advanced thickness gauge
- Sizing toolkits : DAC, AWS, TCG, DGS
- 0–110 dB gain : manual and automatic (AGC)
- 1.8–19 MHz broadband : + selectable narrow bands
- 5.7” color display : sunlight-readable Blanview
- Thickness modes : P-E, PECT, PETP
- PRF 8 Hz–2 kHz : 60 Hz refresh
The FX81-DL is the flagship model of the Dakota flaw detector line: it combines flaw detection (DAC, AWS, TCG, DGS toolkits, Z-Cross/Flank/Peak detection, PRF 8 Hz–2 kHz) with a high-performance receiver offering 0–110 dB gain (0.2 dB resolution), selectable damping and a 1.8–19 MHz broadband with narrow bands.
The large 5.7” QVGA Blanview color display, readable even in sunlight, and the thickness measuring modes (Pulse-Echo, Pulse-Echo Coating, temperature compensation) make it suitable for the most demanding inspections. High horizontal (±0.4% FSW) and vertical (±1% FSH) linearity.

Would you like help choosing the right product ?
Technical characteristics
| Feature | Value |
| Instrument type | Top-of-the-range ultrasonic flaw detector with advanced thickness gauge |
| Sizing toolkits | DAC, AWS, TCG, DGS |
| PRF | 8 Hz – 2 kHz, adjustable |
| Screen refresh | 60 Hz |
| Detection | Z-Cross, Flank and Peak |
| Gain | 0–110 dB with 0.2 dB resolution; manual and AGC |
| Damping | 50 / 75 / 100 / 300 / 600 / 1500 ohm |
| Frequency bands | 1.8–19 MHz broadband (−3 dB); narrow bands at 1/2/5/10/0.5/15 MHz |
| Linearity | Horizontal ±0.4% FSW; vertical ±1% FSH |
| Thickness modes | Pulse-Echo (P-E), Pulse-Echo Coating (PECT), Pulse-Echo Temp Comp (PETP) – dual element |
| Pulse-Echo thickness range | 0.63 mm – 3048 cm |
| PECT range | material from 0.63 mm; coating 0.01–2.54 mm |
| Display | Blanview color TFT QVGA (320×240), 115.2×86.4 mm area (5.7”), 16 colors, variable brightness |
| Software | PC for reporting |
| Dimensions | 216 × 165 × 70 mm |
| Weight | approx. 2.04 kg (4.5 lb, with batteries) |
| Housing | Extruded aluminum with nickel-plated aluminum end caps (sealed gaskets) |
Part numbers, accessories and spare parts
Part numbers for ordering the FX81-DL and its accessories. The part numbers will be added as soon as they are available.
Instrument – complete kit

| Part number | Product code | Description |
| — | FX81-DL | FX81-DL top-of-the-range ultrasonic flaw detector with advanced thickness gauge |
Accessories
Photo
Part number
Product code
Description

—
Transducer
Ultrasonic transducer (angle beam or dual/single element) with quick-release connectors

—
Couplant
Coupling gel for ultrasound transmission

—
USB cable / carrying case
Connection cable and carrying case
Technical documentation
| Document | Type |
| FX81-DL datasheet | Datasheet (PDF) |
Frequently asked questions
The FX81-DL is the top-of-the-range model: 0–110 dB receiver, 1.8–19 MHz broadband with narrow bands, and a large 5.7” sunlight-readable Blanview color display.
DAC, AWS, TCG and DGS, with Z-Cross, Flank and Peak detection and adjustable PRF from 8 Hz to 2 kHz.
Yes: it offers Pulse-Echo, Pulse-Echo Coating (material + coating) and temperature compensation modes.
Yes: a 5.7” Blanview color TFT display, readable in sunlight, with variable brightness.
Contacts & Information
Contact for general information : info@roder.it
Machine Vision Division of RODER : www.rodervision.com
RODER Instruments Division : www.innovacheck.com
More about RODER : about us
The information contained in this website is provided for information purposes only. Although it has been prepared with the greatest care, it does not constitute a contractual offer or a binding commitment to supply. It may contain transcription, translation or typographical errors. For precise and up-to-date information, please contact our company directly.
Note: Some images on this website have been intentionally generated using artificial intelligence (AI). This is because, for many applications and projects, photographs of the actual installation or system cannot be disclosed owing to confidentiality agreements, contractual clauses and non-disclosure agreements (NDAs).
You must be logged in to post a comment.