RODER · Käfer fork thickness gauges
Käfer fork thickness gauges

The Käfer fork thickness gauges distributed by RODER measure the thickness of a wide range of materials – leather, cardboard, paper, felt, rubber, glass, sheet metal, film, plywood and plastic – using an analog or digital dial indicator mounted on a fork (C-frame). The range covers resolutions from 0.1 mm to 0.001 mm, throat depths from 12 to 300 mm and analog, digital (with RS 232 or USB data output) and pocket versions. The interchangeable contact points suit the material and the lifting device ensures a constant measuring force.
On this page
How to choose a fork thickness gauge
- Resolution: 0.1 mm on the K series, 0.01 mm on the J/JD and pocket series, 0.001 mm on the high-resolution F50 and FD50 models.
- Analog or digital: analog dial indicator (K, J, F series) or digital with RS 232 / USB data output (JD, FD series).
- Throat depth: from 12 mm (pocket models) up to 300 mm, to reach points far from the edge of the material.
- Measuring range: from 5 mm (F50) up to 50 mm in the K series variants; 12.5–25 mm on the digital models.
- Portability: the J12 and J15 pocket models for use on the move; the larger models are used on the bench with the 2.1670 column stand.
Model comparison
| Model | Type | Reading / Resolution | Range | Throat | Standard / Accuracy |
|---|---|---|---|---|---|
| K50 | Analog | 0.1 mm | 10 mm | 50 mm | std 0.0500.9.0004 |
| K200 | Analog, lifting device | 0.1 mm | 30 mm | 200 mm | std 0.0500.9.0004 |
| K300 | Analog, lifting device | 0.1 mm | 30 mm | 300 mm | std 0.0500.9.0004 |
| J50 | Analog | 0.01 mm | 10 mm | 50 mm | DIN 878 |
| J100 | Analog, lifting device | 0.01 mm | 10 mm | 100 mm | DIN 878 |
| J200 | Analog, lifting device | 0.01 mm | 10 mm | 200 mm | DIN 878 |
| F50 | Analog, high resolution | 0.001 mm | 5 mm | 50 mm | std 0.0500.9.0001 |
| JD50 | Digital | 0.01 mm | 12.5 mm | 50 mm | max. error 20 µm |
| JD100 | Digital | 0.01 mm | 12.5 mm | 100 mm | max. error 20 µm |
| JD200 | Digital | 0.01 mm | 12.5 mm | 200 mm | max. error 20 µm |
| FD50 | Digital, high resolution | 0.001 mm | 12.5 mm | 50 mm | max. error 5 µm |
| J12 | 0.01 mm | 8 mm | 12 mm | DIN 878 | |
| J15 | 0.01 mm | 10 mm | 18 mm | DIN 878 |
The models
Analog and digital fork thickness gauges for every material
The Käfer range includes analog and digital fork thickness gauges, with resolutions from 0.1 mm down to 0.001 mm (F50 and FD50) and throat depths up to 300 mm, to measure thickness even far from the edge of the material.
For measurements on the move the J12 and J15 pocket models are available, while the JD and FD digital models offer RS 232 or USB data output for transferring measurements to a PC. The interchangeable contact points (shapes a–e) suit the material being measured.
Contacts & Information
Contact for general information : info@roder.it
Machine Vision Division of RODER : www.rodervision.com
RODER Instruments Division : www.innovacheck.com
More about RODER : about us
The information contained in this website is provided for information purposes only. Although it has been prepared with the greatest care, it does not constitute a contractual offer or a binding commitment to supply. It may contain transcription, translation or typographical errors. For precise and up-to-date information, please contact our company directly.
Note: Some images on this website have been intentionally generated using artificial intelligence (AI). This is because, for many applications and projects, photographs of the actual installation or system cannot be disclosed owing to confidentiality agreements, contractual clauses and non-disclosure agreements (NDAs).