DL2 series LED bar illuminators

DL2 series LED illuminator Visiotronix Photolux for vision systems

The DL2 series LED illuminators from Visiotronix Photolux are LED matrix illuminators for the direct lighting of vision systems and optical machines, available with clear or semi-transparent glass, with RMD© driver and HTTM© technology for a stable, homogeneous light emission.

The DL2 series consists of a high density, high brightness LED matrix with integrated lens, for direct lighting in confined spaces. Compared with the DL1 series, the DL2 is available with two types of glass — clear for maximum intensity and directionality, or semi-transparent for a more diffused, uniform light — to match the lighting to the type of surface and inspection.

The anodised aluminium body ensures robustness and heat dissipation; HTTM© technology keeps the luminous flux stable and extends the life of the LEDs, while the controlled current RMD© (RODER Multi Driver) driver guarantees homogeneity and chromatic stability of the emission. It is the ideal choice for system integrators and OEMs.

banner aiuto nella scelta dello strumento oppure della tecnologia

Why choose a DL2 illuminator

  • Two glass options: clear (direct, intense light) or semi-transparent (diffused, uniform light).
  • High density LED matrix with integrated lens for a homogeneous beam.
  • HTTM© technology for a low, uniform junction temperature and a long LED life.
  • RMD© driver (RODER Multi Driver) with controlled current for homogeneity and stability of the light.
  • Industrial 3-pole M8 connector with threaded ring nut and cable with flexible cable gland.
  • Anodised aluminium housing: robustness and heat dissipation; reverse polarity protection.
  • 48h test certificate with every illuminator; latest generation, high efficiency LEDs.

Common technical specifications

M8 connector, HTTM materials and 48-hour burn-in test.Value
Supply voltage24 Vdc ±10%
Degree of protectionIP40
Temperature range10 °C – 50 °C
Electrical connection3-pole M8 connector with threaded ring nut
CertificationsCE · RoHS
Glassclear (A00000) or semi-transparent (A10000)
TechnologiesHTTM© (thermal management) · RMD© (controlled current driver)

Colours, glass and code structure

Every model is available in three emissions — neutral white 5500K (WHI), blue 465 nm (BLU), red 630 nm (RED) — and with two types of glass. The product code follows the scheme PL-DL2-YYYYYY-XXX-AG0000: YYYYYY = area dimensions (mm), XXX = colour, G = type of glass (0 = clear, 1 = semi-transparent).

Models and part numbers

Emission areaColorCurrent drawNo. of LEDsPart no. clear glass Part no. semi-transp. glass
25 x 100 mmWhite 5500K0.12 A @24Vdc6010-00-2414-06-51
25 x 100 mmBlue 465 nm0.12 A @24Vdc6010-00-2314-06-17
25 x 100 mmRed 630 nm0.12 A @24Vdc6010-00-2014-07-22
25 x 200 mmWhite 5500K0.24 A @24Vdc12010-00-3414-06-92
25 x 200 mmBlue 465 nm0.24 A @24Vdc12010-00-3314-07-33
25 x 200 mmRed 630 nm0.24 A @24Vdc12010-00-3014-06-68
25 x 300 mmWhite 5500K0.36 A @24Vdc18010-00-9414-06-74
25 x 300 mmBlue 465 nm0.36 A @24Vdc18010-00-9314-06-33
25 x 300 mmRed 630 nm0.36 A @24Vdc18010-00-9014-06-48
25 x 400 mmWhite 5500K0.48 A @24Vdc24010-01-4414-07-38
25 x 400 mmBlue 465 nm0.48 A @24Vdc24010-01-4314-07-25
25 x 400 mmRed 630 nm0.48 A @24Vdc24010-01-4014-06-31
25 x 500 mmWhite 5500K0.60 A @24Vdc30010-01-5414-06-50
25 x 500 mmBlue 465 nm0.60 A @24Vdc30010-01-5314-05-87
25 x 500 mmRed 630 nm0.60 A @24Vdc30010-01-5014-05-81
50 x 50 mmWhite 5500K0.12 A @24Vdc6010-00-6414-05-97
50 x 50 mmBlue 465 nm0.12 A @24Vdc6010-00-6314-06-00
50 x 50 mmRed 630 nm0.12 A @24Vdc6010-00-6014-06-93
50 x 100 mmWhite 5500K0.24 A @24Vdc12010-00-4414-06-87
50 x 100 mmBlue 465 nm0.24 A @24Vdc12010-00-4314-07-13
50 x 100 mmRed 630 nm0.24 A @24Vdc12010-00-4014-04-62
50 x 200 mmWhite 5500K0.48 A @24Vdc24010-00-5414-05-99
50 x 200 mmBlue 465 nm0.48 A @24Vdc24010-00-5314-06-27
50 x 200 mmRed 630 nm0.48 A @24Vdc24010-00-5014-06-73
50 x 300 mmWhite 5500K0.72 A @24Vdc36010-01-0414-07-29
50 x 300 mmBlue 465 nm0.72 A @24Vdc36010-01-0314-06-44
50 x 300 mmRed 630 nm0.72 A @24Vdc36010-01-0014-06-23
100 x 100 mmWhite 5500K0.48 A @24Vdc24010-00-7414-06-57
100 x 100 mmBlue 465 nm0.48 A @24Vdc24010-00-7314-07-20
100 x 100 mmRed 630 nm0.48 A @24Vdc24010-00-7014-07-32
100 x 200 mmWhite 5500K0.96 A @24Vdc48010-02-1414-06-98
100 x 200 mmBlue 465 nm0.96 A @24Vdc48010-02-1314-06-13
100 x 200 mmRed 630 nm0.96 A @24Vdc48010-02-1014-07-17
100 x 300 mmWhite 5500K1.44 A @24Vdc72010-01-1414-06-58
100 x 300 mmBlue 465 nm1.44 A @24Vdc72010-01-1314-06-14
100 x 300 mmRed 630 nm1.44 A @24Vdc72010-01-1014-06-56

Standard models; other dimensions (up to 25×800 mm) on request. The complete product code is PL-DL2-[area]-[colour]-A0/A1 (0 = clear glass, 1 = semi-transparent).

Typical configurations

  • Direct lighting of the object to be inspected, with the angle of incidence chosen according to the type of control.
  • Low-cost backlight: with a diffusing glass at the optimal distance, a high brightness backlight is obtained (diffuser not supplied as standard).
  • Semi-transparent glass for a softer, more uniform light, useful for reducing reflections on glossy surfaces.

Machine vision systems for quality control on the production line combine cameras and dedicated LED illuminators: ring and coaxial lighting ensures sharp, repeatable images for the automatic detection of defects.

DocumentType
Scarica PDFDL2 illuminator family catalogueCatalogue

Typical applications

Applications built and documented with the DL2 series LED illuminators:

DL2 illuminators for vision with cameras

DL2 illuminators for vision with cameras

The DL2 series LED illuminators provide direct, uniform lighting for vision systems with industrial cameras; the choice of clear or semi-transparent glass makes it possible to match the lighting effect to the type of inspection and to the surface.

Visual inspection of miniaturised components

Visual inspection of miniaturised components

Visual inspection of miniaturized components with machine vision systems calls for compact, uniform LED illuminators: high-intensity direct light reveals defects and details, ensuring accuracy and repeatability in quality control.

Special lighting for in-line vision

Special lighting for in-line vision

Special lighting systems for industrial vision on the production line: LED illuminators with direct light or backlight to enhance the contrast, edges and details of the objects to be inspected on inspection benches.

Frequently asked questions

What is the difference between the DL2 series and the DL1 series?

The two series share the LED matrix for direct lighting; the DL2 is available with clear or semi-transparent glass, integrates the RMD© driver and has a temperature range of 10–50 °C with CE-RoHS certification.

What is semi-transparent glass for?

Semi-transparent glass makes the light more diffused and uniform, reducing reflections and bright spots on glossy surfaces; clear glass instead offers maximum intensity and directionality.

Which colours are available?

Neutral white 5500K, blue 465 nm and red 630 nm, selectable in the product code (WHI/BLU/RED).

How is the DL2 powered?

With a 24 Vdc ±10% voltage through an industrial-standard 3-pole M8 connector with threaded ring nut.

What are the degree of protection and the operating temperature?

IP40 protection rating, temperature range 10–50 °C, with CE and RoHS certification.

Contact for general information : info@roder.it

Machine Vision Division of RODER : www.rodervision.com
RODER Instruments Division : www.innovacheck.com
More about RODER : about us

The information contained in this website is provided for information purposes only. Although it has been prepared with the greatest care, it does not constitute a contractual offer or a binding commitment to supply. It may contain transcription, translation or typographical errors. For precise and up-to-date information, please contact our company directly.

Note: Some images on this website have been intentionally generated using artificial intelligence (AI). This is because, for many applications and projects, photographs of the actual installation or system cannot be disclosed owing to confidentiality agreements, contractual clauses and non-disclosure agreements (NDAs).

Angle inspection Angle measurement Arch gauges Automation systems Billet measurement Bloom measurement Coil measurement Corrosion Deformation measurement Diameter measurement Digital archimeters Dimensional inspection Displacement measurement Distance measurement Force measurement Giant display Industrial automation Laser micrometers Laser profilometer Laser rangefinders Laser sensors Laser thickness measurement Length measurement Level measurement Measuring benches Non-contact distance measurement Non-contact measurement Non-contact position measurement Oscillation measurement Out-of-roundness measurement Ovality measurement Overhead crane measurement Position measurement Profile inspection Profile measurement Profilometers Quality control Remote display monitor Research and development Slab measurement SPC analysis Statistical analysis Statistical control Thickness gauges Thickness measurement

Cosmetics industry news Footwear industry news News agriculture sector News automotive sector News chemical sector News construction sector News electronics and electrical engineering sector News food sector News from the dairy sector News from the livestock farming sector News from the paint, coatings and corrosion sector News marine and shipbuilding sector News mechanical engineering sector News metal and semi-finished products sector News metallurgy and steel sector News mining and quarrying sector News plant construction sector News plastics and rubber sector News rail sector News services sector News steelwork and heavy construction sector News textile sector News university and research sector News wood sector Senza categoria