{"id":23066,"date":"2026-05-13T15:40:55","date_gmt":"2026-05-13T13:40:55","guid":{"rendered":"https:\/\/roder.it\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/"},"modified":"2026-09-28T12:13:06","modified_gmt":"2026-09-28T10:13:06","slug":"salt-dust-and-surface-contamination","status":"publish","type":"page","link":"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/","title":{"rendered":"Salt, dust and surface contamination"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Measuring salt, dust and surface contamination is a critical check in the preparation of steel structures before anti-corrosion coatings are applied. The presence of soluble salts (chlorides, sulfates, nitrates), of dust left by blasting, or of oils, greases and other contaminants on the metal surface seriously compromises the adhesion of the coating and accelerates under-film corrosion (osmosis, blistering, detachment). The technologies available include the Bresle method for soluble salts, the dust tape test for dustiness, and detection kits for organic contamination (oils, greases).  <\/p>\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-cover is-light popmake-11245\" style=\"border-width:1px;border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-left-radius:10px;border-bottom-right-radius:10px;min-height:250px;aspect-ratio:unset;\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"213\" class=\"wp-block-cover__image-background wp-image-14896 size-large\" alt=\"banner aiuto nella scelta dello strumento oppure della tecnologia\" src=\"https:\/\/roder.it\/wp-content\/uploads\/2026\/06\/banner_technical_support_choose_products-1024x213.png\" data-object-fit=\"cover\" srcset=\"https:\/\/roder.it\/wp-content\/uploads\/2026\/06\/banner_technical_support_choose_products-1024x213.png 1024w, https:\/\/roder.it\/wp-content\/uploads\/2026\/06\/banner_technical_support_choose_products-300x63.png 300w, https:\/\/roder.it\/wp-content\/uploads\/2026\/06\/banner_technical_support_choose_products-768x160.png 768w, https:\/\/roder.it\/wp-content\/uploads\/2026\/06\/banner_technical_support_choose_products.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\" style=\"background-color:#d3d6dc\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-a304f9a9 wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-right has-ti-fg-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"font-size:clamp(21.536px, 1.346rem + ((1vw - 3.2px) * 1.726), 35px);\"><strong>Would you like help choosing the right product ?<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-right is-layout-flex wp-container-core-buttons-is-layout-b507c051 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/roder.it\/en\/contacts\/\">Click here !<\/a><\/div>\n<\/div>\n<\/div><\/div>\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<h2 class=\"wp-block-heading\">The Bresle method for soluble salts<\/h2><p class=\"wp-block-paragraph\">The Bresle method (ISO 8502-6, ISO 8502-9) is the most widespread procedure for the quantitative measurement of soluble salts. A transparent adhesive cell (Bresle patch) is stuck to the prepared metal surface; a known volume of deionized water is injected into the cell with a syringe, left in contact for about one minute with agitation, then drawn off. The electrical conductivity of the solution, measured with a calibrated conductivity meter, is proportional to the concentration of salts on the surface. Converted into mg\/m\u00b2 by established formulas, it gives the saline contamination value. Complete kits are available with cells, syringes, a conductivity meter and calibration solutions.    <\/p><h2 class=\"wp-block-heading\">The dust tape test<\/h2><p class=\"wp-block-paragraph\">The dust tape test (ISO 8502-3) measures the dust remaining after blasting: transparent adhesive tape is applied to the surface and the quantity and size of the adhering particles are then compared visually with standardized reference scales (quantity from 0 to 5, size from 1 to 5). The result is expressed as a dustiness category (for example &#8220;dust quantity 2 \/ dust class 3&#8221;). For highly critical surfaces, kits with cameras and automatic image analysis software are used to obtain quantitative results.  <\/p><h2 class=\"wp-block-heading\">Organic contamination<\/h2><p class=\"wp-block-paragraph\">Checking for organic contamination (oils, greases, hydrocarbons) is done by indirect methods: the water-break test (water spreads evenly only on a clean surface), the colored-water test, detection kits with UV fluorescent dyes, and solvent sampling with laboratory analysis. For critical applications (aerospace, food packaging, medical) there are portable UV fluorescence instruments for detecting hydrocarbon residues on metal. <\/p><h2 class=\"wp-block-heading\">Applications<\/h2><p class=\"wp-block-paragraph\">Surface contamination checks are required by the more severe anti-corrosion specifications (marine environments, offshore, the chemical industry): typically a maximum of 50 mg\/m\u00b2 of chlorides for standard marine systems, and 20 mg\/m\u00b2 for very severe environments. Dustiness must generally be classified as &#8220;class 2&#8221; or lower before the primer is applied. Documenting the measurements (with a photograph of the Bresle patch, the conductivity value, the contamination calculation and the comparison against the specification) constitutes objective evidence that the preparation procedures have been followed.  <\/p><h2 class=\"wp-block-heading\">Reference standards<\/h2><p class=\"wp-block-paragraph\">The reference standards are: ISO 8502-1 (extraction and analysis of surface corrosion products), ISO 8502-2 (chlorides on cleaned surfaces), ISO 8502-3 (dust tape test), ISO 8502-6 (Bresle sampling) and ISO 8502-9 (Bresle sampling with a field conductivity meter). Calibration of the conductivity meter is carried out with ISO 17025 certified KCl solutions of known conductivity. Dust test kits must carry standardized visual reference documents.  <\/p><p class=\"wp-block-paragraph\">Integrating the measuring kits with digital reporting systems (mobile apps, dedicated software) allows every inspection to be fully documented: sampling data, a photograph of the Bresle patch, georeferencing of the measuring point, automatic calculations, and generation of campaign reports that comply with the standards. This level of documentation is fundamental in marine and offshore anti-corrosion projects, where conformity with the surface preparation specifications is verified by FROSIO- or NACE-certified inspectors. <\/p>","protected":false},"excerpt":{"rendered":"<p>Instruments for measuring soluble salts (Bresle) and blasting residues on surfaces before painting.<\/p>\n","protected":false},"author":157040980,"featured_media":0,"parent":19361,"menu_order":5,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_yoast_wpseo_focuskw":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","_wpcom_ai_launchpad_about_page":false,"_wpcom_ai_launchpad_gallery_page":false,"_wpcom_ai_launchpad_contact_page":false,"_wpcom_ai_launchpad_events_page":false,"_wpcom_ai_launchpad_video_page":false,"_wpcom_ai_launchpad_portfolio_piece":false,"footnotes":""},"class_list":["post-23066","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Salt, dust and surface contamination - RODER SRL<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Salt, dust and surface contamination - RODER SRL\" \/>\n<meta property=\"og:description\" content=\"Instruments for measuring soluble salts (Bresle) and blasting residues on surfaces before painting.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/\" \/>\n<meta property=\"og:site_name\" content=\"RODER SRL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-28T10:13:06+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/coating-thickness-and-surface-profile\\\/salt-dust-and-surface-contamination\\\/\",\"url\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/coating-thickness-and-surface-profile\\\/salt-dust-and-surface-contamination\\\/\",\"name\":\"Salt, dust and surface contamination - RODER SRL\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#website\"},\"datePublished\":\"2026-05-13T13:40:55+00:00\",\"dateModified\":\"2026-09-28T10:13:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/coating-thickness-and-surface-profile\\\/salt-dust-and-surface-contamination\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/coating-thickness-and-surface-profile\\\/salt-dust-and-surface-contamination\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/coating-thickness-and-surface-profile\\\/salt-dust-and-surface-contamination\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/roder.it\\\/en\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Inspection\",\"item\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Coating thickness and surface profile\",\"item\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/coating-thickness-and-surface-profile\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Salt, dust and surface contamination\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/roder.it\\\/en\\\/\",\"name\":\"RODER SRL\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/roder.it\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#organization\",\"name\":\"RODER SRL\",\"url\":\"https:\\\/\\\/roder.it\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/roder.it\\\/wp-content\\\/uploads\\\/2019\\\/05\\\/logo_roder_standard_sfondo_bianco.png\",\"contentUrl\":\"https:\\\/\\\/roder.it\\\/wp-content\\\/uploads\\\/2019\\\/05\\\/logo_roder_standard_sfondo_bianco.png\",\"width\":691,\"height\":80,\"caption\":\"RODER SRL\"},\"image\":{\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Salt, dust and surface contamination - RODER SRL","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/","og_locale":"en_US","og_type":"article","og_title":"Salt, dust and surface contamination - RODER SRL","og_description":"Instruments for measuring soluble salts (Bresle) and blasting residues on surfaces before painting.","og_url":"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/","og_site_name":"RODER SRL","article_modified_time":"2026-09-28T10:13:06+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/","url":"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/","name":"Salt, dust and surface contamination - RODER SRL","isPartOf":{"@id":"https:\/\/roder.it\/en\/#website"},"datePublished":"2026-05-13T13:40:55+00:00","dateModified":"2026-09-28T10:13:06+00:00","breadcrumb":{"@id":"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/salt-dust-and-surface-contamination\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/roder.it\/en\/home\/"},{"@type":"ListItem","position":2,"name":"Inspection","item":"https:\/\/roder.it\/en\/inspection\/"},{"@type":"ListItem","position":3,"name":"Coating thickness and surface profile","item":"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/"},{"@type":"ListItem","position":4,"name":"Salt, dust and surface contamination"}]},{"@type":"WebSite","@id":"https:\/\/roder.it\/en\/#website","url":"https:\/\/roder.it\/en\/","name":"RODER SRL","description":"","publisher":{"@id":"https:\/\/roder.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/roder.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/roder.it\/en\/#organization","name":"RODER SRL","url":"https:\/\/roder.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/roder.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/roder.it\/wp-content\/uploads\/2019\/05\/logo_roder_standard_sfondo_bianco.png","contentUrl":"https:\/\/roder.it\/wp-content\/uploads\/2019\/05\/logo_roder_standard_sfondo_bianco.png","width":691,"height":80,"caption":"RODER SRL"},"image":{"@id":"https:\/\/roder.it\/en\/#\/schema\/logo\/image\/"}}]}},"jetpack_likes_enabled":false,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/PaWZeX-602","jetpack-related-posts":[{"id":19361,"url":"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/","url_meta":{"origin":23066,"position":0},"title":"Coating thickness and surface profile","author":"GSM","date":"13 May 2026","format":false,"excerpt":"Instruments for measuring the thickness of paint and coatings, blast profile, surface contamination and coating adhesion.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":22364,"url":"https:\/\/roder.it\/en\/inspection\/non-destructive-testing-vibration-optics-and-acoustics\/auxiliary-appearance-tests-dust-tape-cross-cut-pencil\/","url_meta":{"origin":23066,"position":1},"title":"Auxiliary appearance tests (dust tape, cross-cut, pencil)","author":"GSM","date":"13 May 2026","format":false,"excerpt":"Complementary instruments for inspecting painted surfaces: dust tape test, cross-cut, pencil hardness.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":23768,"url":"https:\/\/roder.it\/en\/roughness-comparators-and-specimens\/","url_meta":{"origin":23066,"position":2},"title":"Roughness comparators and specimens","author":"GSM","date":"13 May 2026","format":false,"excerpt":"Visual\/tactile comparison specimens and calibration specimens for verifying roughness testers.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":22986,"url":"https:\/\/roder.it\/en\/inspection\/coating-thickness-and-surface-profile\/blasting-profile-and-replica-tape\/","url_meta":{"origin":23066,"position":3},"title":"Blasting profile and replica tape","author":"GSM","date":"13 May 2026","format":false,"excerpt":"Instruments for measuring the peak-to-valley profile of blasted surfaces, and micrometers for replica tape.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":22208,"url":"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/particle-and-pm-counters\/","url_meta":{"origin":23066,"position":4},"title":"Particle and PM counters","author":"GSM","date":"13 May 2026","format":false,"excerpt":"Particle counters for cleanrooms, IAQ and dust monitoring.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":23375,"url":"https:\/\/roder.it\/en\/inspection\/distance-position-and-displacement-non-contact\/high-resolution-position-and-displacement-sensors\/","url_meta":{"origin":23066,"position":5},"title":"High-resolution position and displacement sensors","author":"GSM","date":"13 May 2026","format":false,"excerpt":"Transducers for measuring displacement, low-frequency vibration and high-precision positioning.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]}],"_links":{"self":[{"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/pages\/23066","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/users\/157040980"}],"replies":[{"embeddable":true,"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/comments?post=23066"}],"version-history":[{"count":3,"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/pages\/23066\/revisions"}],"predecessor-version":[{"id":23069,"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/pages\/23066\/revisions\/23069"}],"up":[{"embeddable":true,"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/pages\/19361"}],"wp:attachment":[{"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/media?parent=23066"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}