{"id":22188,"date":"2026-05-13T15:44:19","date_gmt":"2026-05-13T13:44:19","guid":{"rendered":"https:\/\/roder.it\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/"},"modified":"2026-09-26T22:00:51","modified_gmt":"2026-09-26T20:00:51","slug":"air-flow-meters","status":"publish","type":"page","link":"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/","title":{"rendered":"Air flow meters"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Air flow meters, commonly called capture hoods or flow hoods, are specialized instruments for the direct measurement of the volumetric air flow at supply and return outlets of ventilation, air conditioning and residential mechanical ventilation (MVHR) systems. Unlike anemometers, which measure velocity at a point and require integration over an area to obtain flow, capture hoods \u201ccapture\u201d the entire air flow leaving the outlet and measure its volume over time directly, giving the flow value in m\u00b3\/h or L\/s. They are the instrument of choice for balancing HVAC systems and commissioning new buildings.  <\/p>\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-cover is-light popmake-11245\" style=\"border-width:1px;border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-left-radius:10px;border-bottom-right-radius:10px;min-height:250px;aspect-ratio:unset;\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"213\" class=\"wp-block-cover__image-background wp-image-14896 size-large\" alt=\"banner aiuto nella scelta dello strumento oppure della tecnologia\" src=\"https:\/\/roder.it\/wp-content\/uploads\/2026\/06\/banner_technical_support_choose_products-1024x213.png\" data-object-fit=\"cover\" srcset=\"https:\/\/roder.it\/wp-content\/uploads\/2026\/06\/banner_technical_support_choose_products-1024x213.png 1024w, https:\/\/roder.it\/wp-content\/uploads\/2026\/06\/banner_technical_support_choose_products-300x63.png 300w, https:\/\/roder.it\/wp-content\/uploads\/2026\/06\/banner_technical_support_choose_products-768x160.png 768w, https:\/\/roder.it\/wp-content\/uploads\/2026\/06\/banner_technical_support_choose_products.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\" style=\"background-color:#d3d6dc\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-a304f9a9 wp-block-cover-is-layout-constrained\">\n<p class=\"has-text-align-right has-ti-fg-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"font-size:clamp(21.536px, 1.346rem + ((1vw - 3.2px) * 1.726), 35px);\"><strong>Would you like help choosing the right product ?<\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-right is-layout-flex wp-container-core-buttons-is-layout-b507c051 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/roder.it\/en\/contacts\/\">Click here !<\/a><\/div>\n<\/div>\n<\/div><\/div>\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<h2 class=\"wp-block-heading\">Architecture of the capture hood<\/h2><p class=\"wp-block-paragraph\">The flow hood consists of: a capture hood made of rigid fabric (in various sizes and geometries \u2013 typically 60\u00d760 cm, 90\u00d730 cm, 60\u00d7120 cm, to cover different outlet shapes); a manifold at the base of the hood that channels the flow towards a flow sensor (typically an array of thermal sensors or Pitot tubes measuring the mean velocity in the manifold); and a support structure (handle, tripod) for use while standing, at ceiling heights of up to 3\u20134 meters. The integrated electronics calculate the flow by multiplying the mean velocity by the cross-section of the manifold. <\/p><h2 class=\"wp-block-heading\">Technical characteristics<\/h2><p class=\"wp-block-paragraph\">Capture hoods typically cover flow ranges from 25 to 4000 m\u00b3\/h, with an accuracy of \u00b13% of reading. Resolution is typically 1 m\u00b3\/h. Advanced functions include: automatic compensation for the restriction effect (back-pressure correction) \u2013 the hood itself slightly alters the flow, and the electronics apply correction factors to obtain the \u201cundisturbed\u201d value; campaign memory; USB\/Bluetooth data output for PC software; measurement of both supply and return (with the sign displayed); and automatic calculation of the percentage deviation from the design setpoint.  <\/p><h2 class=\"wp-block-heading\">Applications<\/h2><p class=\"wp-block-paragraph\">Typical use is in: commissioning new HVAC systems (checking the correct distribution of the design flow rates at every outlet in the building); balancing existing air systems (adjusting the balancing dampers to achieve the correct flow at each terminal); periodic maintenance checks (to identify drift in the system, deposits in the ducts, deterioration of filters, problems with fan motors); acceptance testing of operating theaters (with flow rates prescribed by regulation); acceptance testing of cleanrooms (in accordance with ISO 14644); and acceptance testing of residential MVHR systems (for energy certification).<\/p><h2 class=\"wp-block-heading\">Internal measurement technology<\/h2><p class=\"wp-block-paragraph\">Capture hoods use two main technologies to measure velocity in the manifold: an array of hot-wire sensors (typically 8\u201316 sensors distributed evenly across the manifold area, for measurements independent of asymmetric velocity profiles), or multiple Pitot tubes with an internal low-pressure differential manometer. Hot-wire arrays offer better accuracy at low flows and with irregular profiles; Pitot tubes are more rugged and less sensitive to dust, but less sensitive at low velocities. Advanced models combine both technologies to optimize performance across all ranges.  <\/p><h2 class=\"wp-block-heading\">Reference standards<\/h2><p class=\"wp-block-paragraph\">The main standards are: EN 12599 (testing and commissioning of building ventilation systems); ASHRAE 111 (USA, HVAC commissioning); ISO 14644-3 (testing and commissioning of cleanrooms); UNI EN 12792 (HVAC terminology). Periodic calibration of capture hoods is carried out in reference wind tunnels with ISO 17025 traceability, at a minimum of 5 points across the range. The typical interval is annual for intensive professional use. Correct measurement procedures (correct positioning of the hood on the outlet, stabilization time, measurement sequence) are critical to the reliability of the balancing.   <\/p><h2 class=\"wp-block-heading\">Selection criteria<\/h2><p class=\"wp-block-paragraph\">The choice depends on the typical outlet sizes encountered in projects (the various hood models come in different sizes and suit different outlet shapes); on the flow range required (low flows for residential MVHR, high flows for commercial HVAC); on portability (weight, folded dimensions); on the reporting software functions; and on the data interfaces for integration with company BMS balancing software. Manufacturers offer complete kits with telescopic handles, interchangeable hoods and accessories for special geometries. <\/p>","protected":false},"excerpt":{"rendered":"<p>Instruments for measuring air flow at ventilation outlets and in air handling systems.<\/p>\n","protected":false},"author":157040980,"featured_media":0,"parent":19489,"menu_order":4,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_yoast_wpseo_focuskw":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","_wpcom_ai_launchpad_about_page":false,"_wpcom_ai_launchpad_gallery_page":false,"_wpcom_ai_launchpad_contact_page":false,"_wpcom_ai_launchpad_events_page":false,"_wpcom_ai_launchpad_video_page":false,"_wpcom_ai_launchpad_portfolio_piece":false,"footnotes":""},"class_list":["post-22188","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Air flow meters - RODER SRL<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Air flow meters - RODER SRL\" \/>\n<meta property=\"og:description\" content=\"Instruments for measuring air flow at ventilation outlets and in air handling systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/\" \/>\n<meta property=\"og:site_name\" content=\"RODER SRL\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-26T20:00:51+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/pressure-air-gas-and-combustion\\\/air-flow-meters\\\/\",\"url\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/pressure-air-gas-and-combustion\\\/air-flow-meters\\\/\",\"name\":\"Air flow meters - RODER SRL\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#website\"},\"datePublished\":\"2026-05-13T13:44:19+00:00\",\"dateModified\":\"2026-09-26T20:00:51+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/pressure-air-gas-and-combustion\\\/air-flow-meters\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/pressure-air-gas-and-combustion\\\/air-flow-meters\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/pressure-air-gas-and-combustion\\\/air-flow-meters\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/roder.it\\\/en\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Inspection\",\"item\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Pressure, air, gas and combustion\",\"item\":\"https:\\\/\\\/roder.it\\\/en\\\/inspection\\\/pressure-air-gas-and-combustion\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Air flow meters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/roder.it\\\/en\\\/\",\"name\":\"RODER SRL\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/roder.it\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#organization\",\"name\":\"RODER SRL\",\"url\":\"https:\\\/\\\/roder.it\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/roder.it\\\/wp-content\\\/uploads\\\/2019\\\/05\\\/logo_roder_standard_sfondo_bianco.png\",\"contentUrl\":\"https:\\\/\\\/roder.it\\\/wp-content\\\/uploads\\\/2019\\\/05\\\/logo_roder_standard_sfondo_bianco.png\",\"width\":691,\"height\":80,\"caption\":\"RODER SRL\"},\"image\":{\"@id\":\"https:\\\/\\\/roder.it\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Air flow meters - RODER SRL","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/","og_locale":"en_US","og_type":"article","og_title":"Air flow meters - RODER SRL","og_description":"Instruments for measuring air flow at ventilation outlets and in air handling systems.","og_url":"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/","og_site_name":"RODER SRL","article_modified_time":"2026-09-26T20:00:51+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/","url":"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/","name":"Air flow meters - RODER SRL","isPartOf":{"@id":"https:\/\/roder.it\/en\/#website"},"datePublished":"2026-05-13T13:44:19+00:00","dateModified":"2026-09-26T20:00:51+00:00","breadcrumb":{"@id":"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/air-flow-meters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/roder.it\/en\/home\/"},{"@type":"ListItem","position":2,"name":"Inspection","item":"https:\/\/roder.it\/en\/inspection\/"},{"@type":"ListItem","position":3,"name":"Pressure, air, gas and combustion","item":"https:\/\/roder.it\/en\/inspection\/pressure-air-gas-and-combustion\/"},{"@type":"ListItem","position":4,"name":"Air flow meters"}]},{"@type":"WebSite","@id":"https:\/\/roder.it\/en\/#website","url":"https:\/\/roder.it\/en\/","name":"RODER SRL","description":"","publisher":{"@id":"https:\/\/roder.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/roder.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/roder.it\/en\/#organization","name":"RODER SRL","url":"https:\/\/roder.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/roder.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/roder.it\/wp-content\/uploads\/2019\/05\/logo_roder_standard_sfondo_bianco.png","contentUrl":"https:\/\/roder.it\/wp-content\/uploads\/2019\/05\/logo_roder_standard_sfondo_bianco.png","width":691,"height":80,"caption":"RODER SRL"},"image":{"@id":"https:\/\/roder.it\/en\/#\/schema\/logo\/image\/"}}]}},"jetpack_likes_enabled":false,"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/PaWZeX-5LS","jetpack-related-posts":[{"id":19951,"url":"https:\/\/roder.it\/en\/technologies\/optics-and-laser\/","url_meta":{"origin":22188,"position":0},"title":"Optics and LASER","author":"GSM","date":"29 June 2026","format":false,"excerpt":"Optical and laser technologies make it possible to measure the speed and length of a moving material without any physical contact. On this page we examine, from a technical standpoint, the principles on which ASTech optical speed meters and encoders are based: the spatial filter of the VLM500 series and\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"scanner laser misura di profilo e posizione","src":"https:\/\/i0.wp.com\/roder.it\/wp-content\/uploads\/2025\/02\/application_note_0001_scansione_laser_rilievo_posizione_aletta_per_saldatura_720x720.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/roder.it\/wp-content\/uploads\/2025\/02\/application_note_0001_scansione_laser_rilievo_posizione_aletta_per_saldatura_720x720.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/roder.it\/wp-content\/uploads\/2025\/02\/application_note_0001_scansione_laser_rilievo_posizione_aletta_per_saldatura_720x720.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/roder.it\/wp-content\/uploads\/2025\/02\/application_note_0001_scansione_laser_rilievo_posizione_aletta_per_saldatura_720x720.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":20637,"url":"https:\/\/roder.it\/en\/inspection\/non-destructive-testing-vibration-optics-and-acoustics\/spectrophotometers-and-colorimeters\/","url_meta":{"origin":22188,"position":1},"title":"Spectrophotometers and colorimeters","author":"GSM","date":"13 May 2026","format":false,"excerpt":"Portable and benchtop instruments for L*a*b* color measurement, CIE references and shade control.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":22198,"url":"https:\/\/roder.it\/de\/pruefungen\/druck-luft-gas-und-verbrennung\/luftdurchflussmessgeraete\/","url_meta":{"origin":22188,"position":2},"title":"Luftdurchflussmessger\u00e4te","author":"GSM","date":"13 May 2026","format":false,"excerpt":"Ger\u00e4te zur Messung des Luftvolumenstroms an L\u00fcftungsausl\u00e4ssen und in l\u00fcftungstechnischen Anlagen.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]},{"id":20197,"url":"https:\/\/roder.it\/en\/industrial-electronics\/ltm-1000-series-laser-thickness-gauges\/","url_meta":{"origin":22188,"position":3},"title":"LTM-1000 series LASER thickness gauges","author":"GSM","date":"4 June 2019","format":false,"excerpt":"laser thickness gauge for non-contact thickness measurement RODER presents the LTM-1000, the new non-contact measuring systems for thickness and width measurement using LASER technology.Used in all applications that call for an economical, easy-to-use system, the LTM-1000 measures the thickness or width of continuous or discontinuous materials by means of laser\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"laser thickness gauge for non-contact thickness measurement","src":"https:\/\/i0.wp.com\/roder.it\/wp-content\/uploads\/2019\/06\/laser_thicknness_gauge_rear_ltm1000.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":18346,"url":"https:\/\/roder.it\/en\/products\/stroboscopes-for-industrial-applications\/","url_meta":{"origin":22188,"position":4},"title":"Stroboscopes for industrial applications","author":"GSM","date":"2 January 2026","format":false,"excerpt":"RODER \u00b7 Shimpo stroboscopes Shimpo stroboscopes for industrial applications The Shimpo stroboscopes distributed by RODER allow non-contact inspection of moving parts: by lighting the object at the right frequency it can be observed as if stationary or in slow motion. The range covers LED and xenon models, battery-powered portable or\u2026","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"stroboscopi portatili alimentati a batteria","src":"https:\/\/i0.wp.com\/roder.it\/wp-content\/uploads\/2019\/06\/prodotti_stroboscopi.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":19297,"url":"https:\/\/roder.it\/en\/inspection\/automatic-dimensional-measurement-and-vision-systems\/","url_meta":{"origin":22188,"position":5},"title":"Automatic dimensional measurement and vision systems","author":"GSM","date":"13 May 2026","format":false,"excerpt":"Integrated systems for dimensional and geometrical inspection in production and in the laboratory: multi-gauge stations, LVDT, machine vision, CMM.","rel":"","context":"Similar post","block_context":{"text":"Similar post","link":""},"img":{"alt_text":"","src":"","width":0,"height":0},"classes":[]}],"_links":{"self":[{"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/pages\/22188","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/users\/157040980"}],"replies":[{"embeddable":true,"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/comments?post=22188"}],"version-history":[{"count":3,"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/pages\/22188\/revisions"}],"predecessor-version":[{"id":22191,"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/pages\/22188\/revisions\/22191"}],"up":[{"embeddable":true,"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/pages\/19489"}],"wp:attachment":[{"href":"https:\/\/roder.it\/en\/wp-json\/wp\/v2\/media?parent=22188"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}